The U series detectors are four channel detectors with full featured LCD interface.
- Meets or exceeds NEMA TS 1 specification
- Patented Audible Detect Signal on all versions.
- Directional Logic capability
- Auxillary connector allows Phase Green Input for each channel
|
- Back-lit LCD screen displays complete detector status and function settings:
- Eliminates guess work and provides critical information necessary for proper detector setup
- Provides accurate, direct visual feedback of channel frequency and sensitivity settings
- Allows easy access to built-in detector diagnostic features
- Upgrades or addition of user specific options are easily accomplished by changing the socket mounted processor
- Push button programming ensures long term reliability by eliminating switch contacts
- All programmed detector parameters are stored in non-volatile memory
- Relay or solid-state output versions available
- CALL delay & CALL extension
- Loop fail diagnostics & memory log
|
|
Ordering information:
Model U-1200-z
|
|
| |
z =
|
R: Relay outputs
SS: Solid-state outputs
Intentionally Left Blank
Includes Programmable Options 1-5 & 9-12
Intentionally Left Blank
|
Requires 804 series harness.
Harness 415-2104-10 required for phase green inputs.
Intentionally Left Blank |
|
| |
|